Sign In | Join Free | My burrillandco.com
Home > Analog Digital Oscilloscope >

LeCroy 20GHz Digital Oscilloscope Practical WaveMaster SDA820Zi-A

Shenzhen Meigaolan Electronic Instrument Co. Ltd
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap LeCroy 20GHz Digital Oscilloscope Practical WaveMaster SDA820Zi-A from wholesalers
     
    Buy cheap LeCroy 20GHz Digital Oscilloscope Practical WaveMaster SDA820Zi-A from wholesalers
    • Buy cheap LeCroy 20GHz Digital Oscilloscope Practical WaveMaster SDA820Zi-A from wholesalers
    • Buy cheap LeCroy 20GHz Digital Oscilloscope Practical WaveMaster SDA820Zi-A from wholesalers
    • Buy cheap LeCroy 20GHz Digital Oscilloscope Practical WaveMaster SDA820Zi-A from wholesalers
    • Buy cheap LeCroy 20GHz Digital Oscilloscope Practical WaveMaster SDA820Zi-A from wholesalers
    • Buy cheap LeCroy 20GHz Digital Oscilloscope Practical WaveMaster SDA820Zi-A from wholesalers

    LeCroy 20GHz Digital Oscilloscope Practical WaveMaster SDA820Zi-A

    Ask Lasest Price
    Brand Name : LeCroy
    Model Number : SDA820Zi-A
    Price : Negotiation
    Payment Terms : T/T
    Supply Ability : in stock
    • Product Details
    • Company Profile

    LeCroy 20GHz Digital Oscilloscope Practical WaveMaster SDA820Zi-A

    Tektronix LeCroy WaveMaster SDA820Zi-A 20 GHz 4 CH
    Description of Tektronix SDA820Zi-A
    Key Features
    • Up to 30 GHz bandwidth and 80 GS/s sample rate
    • The most advanced oscilloscope user interface
    • The industry’s only true hardware 14.1 Gb/s serial trigger
    • Low Jitter Measurement Floor and exceptional timebase stability
    • Comprehensive set of serial data analysis, debug, validation and compliance tools
    • Integrated 50 Ω and 1 MΩ inputs for true connection and probing flexibility
    • Integrated standard and custom measurements and math functions for unrivaled analysis capability
    • Multi-lane serial data eye, jitter and crosstalk analysis
    • Real-time de-embedding, emulation, and equalization

    Exceptional Performance

    With up to 30 GHz bandwidth, 80 GS/s sample rate, extremely stable timebase and a 14.1 Gb/s serial trigger the WaveMaster 8 Zi-B has the hardware performance to capture today’s high-speed signals.

    Revolutionary Usability

    The WaveMaster 8Zi-B is a sophisticated instrument, designed for solving complex problems. But the MAUI user interface, along with the WaveMaster 8Zi-B’s 15.3” high-resolution touchscreen, makes advanced analysis easy to set up and use. A flat menu structure puts the most common tools in the easiest reach. Sophisticated multi-grid displays are easy to configure. Vertical, horizontal and acquisition setting changes are made without obscuring waveform display.

    Made to Solve

    MAUI provides the most tightly-integrated toolset of any oscilloscope user interface. Track measured parameters across acquisitions, trend their variations on longer timescales, or visualize and measure their distributions using histograms. Chain multiple measurements and math functions together to easily create custom analysis features for your applications. Integrate third-party programming environments, such as MATLAB, directly into the scope’s processing stream for even more customization.

    Debug and Validation Made Easy

    Connecting a problem with its root cause often requires looking at the signal in multiple domains. The WaveMaster 8Zi-B allows you to combine multiple analysis types into a single, correlated display: analog signals, protocol decodes, eye diagrams, measurement parameters, and other relevant information are presented side-by-side, in real-time.

    Configurations Optimized for Serial Data Analysis

    The SDA 8 Zi-B models have been specifically configured to handle today’s most challenging serial data applications. As well as doubling the standard memory depth, the SDA 8 Zi-B comes as standard with a 6.5 Gb/s true hardware serial pattern trigger, and the SDAIII core toolset, which provides tightly-integrated and comprehensive eye diagram and jitter analysis for NRZ signals.

    SDAIII toolset

    The Teledyne LeCroy SDAIII-CompleteLinQ Serial Data Analysis products contain multilane eye and jitter analysis, LaneScape™ comparison modes, vertical noise measurements, and crosstalk analysis tools. These capabilities provide the deepest insight into the behavior of multi- or single-lane serial data systems.

    Decode From Bit-level to Protocol Layer

    Decoders are available for over 20 low-speed and high-speed serial data buses. These fully-integrated analysis tools annotate the acquired analog waveform with the corresponding decoded data, as well as providing a comprehensive, exportable decode table.

    For many standards, ProtoSync allows a view from even higher up the protocol stack, linking the physical-layer waveforms to full transaction- and protocol-layer analysis.

    Automated Compliance Testing

    Teledyne LeCroy’s QualiPHY software makes it easy to perform automated compliance tests and produce comprehensive test reports on a wide array of serial standards including:

    • PCI Express (1.0, 2.0, 3.0)
    • USB1, USB2, USB 3.0
    • DDR2, LPDDR2, DDR3, LPDDR3, DDR4
    • SAS2, SAS3, SATA
    • MIPI D-PHY, MIPI M-PHY
    • 10/100/100 BASE-T, 10GBASE-T, 10GBASE-KR, SFI
    • HDMI 1.4, DisplayPort 1.2
    • MOST50, MOST150, BroadR-Reach

    Vertical System

    Analog Bandwidth (Max) 20 GHz
    Analog Bandwidth @ 50 Ω (-3 dB) (ProLink Input) 20 GHz (≥10 mV/div)
    Analog Bandwidth @ 50 Ω (-3 dB) (ProBus Input) 3.5 GHz (≥10 mV/div)
    Analog Bandwidth @ 1 MΩ (-3 dB) (ProBus Input) 500 MHz (typical, ≥2 mV/div)
    Rise Time (10-90%, 50 Ω) 22 ps (test limit, flatness mode)
    Rise Time (20-80%, 50 Ω) 16.5 ps (flatness mode)
    Input Channels 4 (Any combination of ProLink and ProBus inputs)
    Bandwidth Limiters 20 MHz, 200 MHz, 1 GHz, 4 GHz, 6 GHz, 8 GHz, 13 GHz, 16 GHz
    Input Impedance ProLink Inputs: 50 Ω+/-2% for ≤100 mV/div, 50 Ω+/-3% for >100 mV/div ProBus Inputs: 50 Ω+/-2% or 1 MΩ||16pF, 10 MΩ || 11 pF with supplied Probe
    Input Coupling ProLink Inputs - 50 Ω: DC, GND ProBus Inputs - 1 MΩ: AC, DC, GND; 50 Ω: DC, GND
    Maximum Input Voltage 50 Ω (ProLink): ±2 Vmax@≤100mV/div, 5.5Vrms@>100mV/div 50 Ω (ProBus): ±5 Vmax, 3.5 Vrms 1 MΩ (ProBus): 250 V max. (peak AC: < 10 kHz + DC)
    Channel-Channel Isolation DC to 10 GHz: 50 dB (>315:1) 10 to 15 GHz: 46 dB (>200:1) 15 to 20 GHz: 40 dB (>100:1) (For any two ProLink input channels, same or different v/div settings, typical)
    Vertical Resolution 8 bits; up to 11 bits with enhanced resolution (ERES)
    Sensitivity 50 Ω (ProLink): 2 mV-1 V/div, fully variable (2-9.9 mV/div via zoom) 50 Ω (ProBus): 2 mV-1 V/div, fully variable; 1 MΩ (ProBus): 2 mV-10 V/div, fully variable
    DC Vertical Gain Accuracy (Gain Component of DC Accuracy) ±1% F.S. (typical), offset at 0V; ±1.5% F.S. (test limit), offset at 0V
    Vertical Noise Floor (50 mV/div) 2.20 mVrms (typical)
    Offset Range 50 Ω (ProLink): ±500 mV @ 2-100 mV/div ±4 V @ >100 mV/div -1 V/div 50 Ω (ProBus): ±750 mV @ 2-100 mV/div ±4 V @ >100 mV/div -1 V/div 1 MΩ: ±1V @ 2-140 mV/div ±10V @ 142mV-1.40V/div ±100V @ 1.42V-10V/div
    DC Vertical Offset Accuracy ±(1.5% of offset setting + 1.5% F.S. + 1 mV) (test limit)

    Horizontal System

    Timebases Internal timebase common to 4 input channels
    Time/Division Range 20 ps/div-128 s/div (Real-Time Mode: 20 ps/div - 64 s/div; RIS mode: 20 ps/div - 10 ns/div, user selectable at ≤10ns/div; Roll mode: 100 ms/div up to 128 s/div, user selectable at ≥100 ms/div and ≤5 MS/s), depending on memory length
    Clock Accuracy < 1 ppm + (aging of 0.5ppm/yr from last calibration)
    Sample Clock Jitter up to 10µs Acquired Time Range: 100fsrms (Internal Timebase Reference)up to 6.4ms Acquired Time Range: 150fsrms (Internal Timebase Reference)
    Delta Time Measurement Accuracy √2*√((Noise/SlewRate)^2+(Sample Clock Jitter)^2 ) (RMS)+(clock accuracy*reading)(seconds)
    Jitter Measurement Floor √((Noise/SlewRate)^2+(Sample Clock Jitter)^2 ) secondsrms (TIE)
    Jitter Between Channels <250fsrms (TIE, typical, measured at maximum bandwidth)
    Trigger and Interpolator Jitter <0.1 ps rms (typical, software assisted), 2 ps rms (typical, hardware),
    Channel-Channel Deskew Range ±9 x time/div. setting or 25 ns max. (whichever is larger), each channel
    External Timebase Reference (Input) 10 MHz; 50 Ω impedance, applied at the rear input
    External Timebase Reference (Output) 10 MHz; 50 Ω impedance, output at the rear

    Acquisition System

    Single-Shot Sample Rate/Ch 40 GS/s on 4 Ch (80 GS/s on 2 Ch using optional WM8Zi-2X80GS External Interleaving Device)
    Random Interleaved Sampling (RIS) 200 GS/s for repetitive signals (20 ps/div to 10 ns/div)
    Maximum Trigger Rate 1,000,000 waveforms/second (in Sequence Mode, up to 4 channels)
    Intersegment Time 1 µs
    Standard Memory (4 Ch / 2 Ch / 1Ch) (Number of Segments) 20 M / 20 M / 20M (Memory and Sample Rate can be doubled in 1 or 2 Ch mode with use of WM8Zi-2X80GS External Interleaving Device) (2000)
    Memory Options (4 Ch / 2 Ch / 1Ch) (Number of Segments) S-32 Option: 32M / 32M / 32M (7,500) M-64 Option: 64M / 64M / 64M (15,000) L-128 Option: 128M / 128M / 128M (15,000) VL-256 Option: 256M / 256M / 256M (15,000) Note: On all memory options, WM8Zi-2X80GS External Interleaving Device permits 80 GS/s on 1 or 2ch with twice the memory)

    Acquisition Processing

    Averaging Summed averaging to 1 million sweeps; continuous averaging to 1 million sweeps
    Enhanced Resolution (ERES) From 8.5 to 11 bits vertical resolution
    Envelope (Extrema) Envelope, floor, or roof for up to 1 million sweeps
    Interpolation Linear or Sin x/x

    Triggering System

    Modes Normal, Auto, Single, and Stop
    Sources Any input channel, Aux, Aux/10, Line, or Fast Edge. Slope and level unique to each source (except line trigger)
    Coupling Mode DC, AC, HFRej, LFRej
    Pre-trigger Delay 0-100% of memory size (adjustable in 1% increments of 100 ns)
    Post-trigger Delay 0-10,000 divisions in real time mode, limited at slower time/div settings or in roll mode
    Hold-off by Time or Events From 2 ns up to 20 s or from 1 to 99,999,999 events
    Internal Trigger Range ±4.1 div from center
    Trigger Sensitivity with Edge Trigger ProBus Inputs 2 div @ < 3.5 GHz, 1.5 div @ < 1.75 GHz, 1.0 div @ < 200 MHz, (for DC coupling, ≥ 10 mV/div, 50 Ω )
    Trigger Sensitivity with Edge Trigger ProLink Inputs 3 div @ < 15 GHz, 1.5 div @ < 3 GHz, 1.0 div @ < 200 MHz, (for DC, AC, LFRej coupling, ≥ 10 mV/div, 50 Ω )
    External Trigger Sensitivity, (Edge Trigger) 2 div @ < 1 GHz, 1.5 div @ < 500 MHz, 1.0 div @ < 200 MHz, (for DC coupling)
    Max. Trigger Frequency, SMART Trigger 2.0 GHz @ ≥ 10 mV/div (minimum triggerable width 200 ps)
    External Trigger Input Range Aux (±0.4 V); Aux/10 (±4 V)

    Basic Triggers

    Edge Triggers when signal meets slope (positive, negative, or either) and level condition.
    Window Triggers when signal exits a window defined by adjustable thresholds
    TV-Composite Video Triggers NTSC or PAL with selectable line and field; HDTV (720p, 1080i, 1080p) with selectable frame rate (50 or 60 Hz) and Line; or CUSTOM with selectable Fields (1-8), Lines (up to 2000), Frame Rates (25, 30, 50, or 60 Hz), Interlacing (1:1, 2:1, 4:1, 8:1), or Synch Pulse Slope (Positive or Negative).

    SMART Triggers

    State or Edge Qualified Triggers on any input source only if a defined state or edge occurred on another input source. Holdoff between sources is selectable by time or events.
    Qualified First In Sequence acquisition mode, triggers repeatably on event B only if a defined pattern, state, or edge (event A) is satisfied in the first segment of the acquisition. Holdoff between sources is selectable by time or events.
    Dropout Triggers if signal drops out for longer than selected time between 1 ns and 20 s.
    Pattern Logic combination (AND, NAND, OR, NOR) of 5 inputs (4 channels and external trigger input). Each source can be high, low, or don't care. The High and Low level can be selected independently. Triggers at start or end of the pattern.

    SMART Triggers with Exclusion Technology

    Glitch Triggers on positive or negative glitches with widths selectable as low as 200ps to 20 s, or on intermittent faults.
    Width (Signal or Pattern) Triggers on positive, negative, or both widths with widths selectable as low as 200ps to 20 s, or on intermittent faults.
    Interval (Signal or Pattern) Triggers on intervals selectable between 1 ns and 20 s.
    Timeout (State/Edge Qualified) Triggers on any source if a given state (or transition edge) has occurred on another source. Delay between sources is 1 ns to 20 s, or 1 to 99,999,999 events.
    Runt Trigger on positive or negative runts defined by two voltage limits and two time limits. Select between 1 ns and 20 ns.
    Slew Rate Trigger on edge rates. Select limits for dV, dt, and slope. Select edge limits between 1 ns and 20 ns.
    Exclusion Triggering Trigger on intermittent faults by specifying the expected behavior and triggering when that condition is not met

    Cascade (Sequence) Triggering

    Capability Arm on "A" event, then Trigger on "B" event. Or Arm on "A" event, then Qualify on "B" event, and Trigger on "C" event.
    Types Cascade A then B: Edge, Window, Pattern (Logic) Width, Glitch, Interval, Dropout, or Measurement. Measurement can be on Stage B only. Cascade A then B then C (Measurement): Edge, Window, Pattern (Logic), Width, Glitch, Interval, Dropout, or Measurement. Measurement can be on Stage C only. Cascade A then B then C: Edge, Window, Pattern (Logic)
    Holdoff Holdoff between A and B or B and C is selectable by time (1ns to 20s) or number of events. Measurement trigger selection as the last stage in a Cascade precludes a holdoff setting between the prior stage and the last stage.

    High Speed Serial Protocol Triggering

    Data Rates Option WM8Zi-6GBIT-80B-8B10B-TD: 600 Mb/s to 6.5 Gb/s, Channel 4 input only Option WM8Zi-14GBIT-80B-8B10B-TD: 600 Mb/s to 14.1 Gb/s, Channel 4 input only
    Pattern Length 80 bits NRZ, eight 8b/10b symbols
    Clock and Data Outputs No Clock and Data Recovery outputs provided

    Low Speed Serial Protocol Triggering (Optional)

    Optionally available I2C, SPI (SPI, SSPI, SIOP), UART-RS232, CAN, LIN, FlexRay, I2S (Audio), MIL-1553

    Measurement Trigger

    Measurement Trigger Capability Select from a large number of measurement parameters trigger on a measurement value with qualified limits. Can be used as only trigger or last event in a Cascade Trigger.

    Color Waveform Display

    Type Color 15.3" flat panel TFT-Active Matrix LCD with high resolution touch screen
    Resolution WXGA; 1280 x 768 pixels.
    Number of traces Display a maximum of 16 traces (up to 40 with some software options). Simultaneously display channel, zoom, memory and math traces.
    Grid Styles Auto, Single, Dual, Quad, Octal, X-Y, Single+X-Y, Dual+X-Y
    Waveform Representation Sample dots joined, or sample dots only

    Internal Waveform Memory

    Internal Waveform Memory 12 active waveform memory traces (M1-M12) store 16 bit/point full length waveforms. Waveforms can be stored to any number of files limited only by the data storage media capacity.

    Integrated Second Display

    Type Supports touch screen integration of user-supplied second display with split-grid capability. (Note: touch screen driver for second display may not be a Fujitsu driver)
    Resolution Determined by display chosen by user

    LeCroy WaveStream™ Fast Viewing Mode

    Intensity 256 Intensity Levels, 1-100% adjustable via front panel control
    Types Select analog or color-graded
    Number of Channels up to 4 simultaneously
    Max Sampling Rate 40 GS/s (80 GS/s with optional WM8Zi-2X80GS external interleaving device)
    Persistence Aging Select from 500 ms to Infinity
    Waveforms/second (continuous) up to 2500 Waveforms/second
    Operation Front panel toggle between WaveStream ON (Analog), ON (Color) and OFF

    Analog Persistence Display

    Analog and Color-Graded Persistence Variable saturation levels; stores each trace's persistence data in memory
    Persistence Types Select analog, color, or three-dimensional
    Trace Selection Activate persistence on all or any combination of traces
    Persistence Aging Select from 500 ms to infinity
    Sweep Display Modes All accumulated, or all accumulated with last trace highlighted

    High Speed Digitizer Output (Option)

    Type LeCroy LSIB
    Transfer Rate up to 325 MB/s (typical)
    Output Protocol PCI Express, Gen 1 (4 lanes utilized for data transfer)
    Control Protocol TCP/IP
    Command Set Via Windows Automation, or via LeCroy Remote Command Set

    Processor/CPU

    Type Intel® CoreTM i7-2600 Quad, 2.6 GHz (up to 3.8 GHz in Turbo mode) (or better)
    Processor Memory 8 GB standard for STD memory (20 Mpt), S-32 and M-64 memory options 16 GB standard for L-128 and VL-256 memory options Up to 32 GB optional
    Operating System Microsoft Windows® 7 Professional Edition (64-bit)
    Real Time Clock Date and time displayed with waveform in hardcopy files. SNTP support to synchronize to precision internal clocks.

    Zoom Expansion Traces

    Zoom Expansion Traces Display up to 12 Zoom and 12 Math/Zoom traces

    Setup Storage

    Front Panel and Instrument Status Store to the internal hard drive, over the network, or to a USB-connected peripheral device.

    Interface

    Remote Control Via Windows Automation, or via LeCroy Remote Command Set
    Network Communication Standard VXI-11 or VICP, LXI Class C (v1.2) Compliant
    GPIB Port Supports IEEE - 488.2
    LSIB Port (optional) Supports PCIe Gen1 x4 protocol with LeCroy supplied API
    Ethernet Port Supports 10/100/1000BaseT Ethernet interface (RJ45 port)
    USB Ports minimum 6 total (incl. 3 front panel) USB 2.0 ports support Windows compatible devices
    External Monitor Port 15 pin D-Type WXGA compatible to support customer-supplied external monitor. Includes support for extended desktop operation with second monitor.
    Peripheral Bus LeCroy LBUS standard

    Auxiliary Input

    Signal Types For External Trigger Input
    Coupling 50 Ω: DC; 1 MΩ: AC, DC, GND
    Max. Input Voltage 50 Ω: 5 Vrms; 1 MΩ: 250 V (Peak AC < 10 kHz + DC)

    Auxiliary Output

    Signal Types Select from calibrator, control signals or Off
    Output Signal 500 Hz-5 MHz square wave or DC level; 0.0 to 500 mV into 50 Ω (0-1 V into 1 MΩ)
    Control Signals Trigger enabled, trigger out, pass/fail status, off
    Connector Type BNC, located on front

    Automatic Setup

    Auto Setup Automatically sets timebase, trigger, and sensitivity to display a wide range of repetitive signals
    Find Vertical Scale Automatically sets the vertical sensitivity and offset for the selected channel to display a waveform with the maximum dynamic range

    General

    Auto Calibration Ensures specified DC and timing accuracy is maintained for 1 year minimum.

    Probes

    Probes Qty. (4) ÷10 Passive Probes
    Probe System Probus and ProLink. Automatically detects and supports a variety of compatible probes
    Scale Factors Automatically or manually selected depending on probe used
    Calibration Output Cal Output: 1kHz square wave, 1Vp-p (typical), output to probe hook. Fast Edge output: 5MHz square wave, 350mVp-p (typical), 50ps rise time, output to SMA connector, AC Coupled.

    Power Requirements

    Voltage 100-240 VAC ±10% at 45-66 Hz; 100-120 VAC ±10% at 380-420 Hz; Automatic AC Voltage Selection, Installation Category II
    Max. Power Consumption 975 W / 975 VA

    Environmental and Safety

    Temperature (Operating) +5 °C to +40 °C including CD-RW/DVD-ROM drive
    Temperature (Non-Operating) -20 °C to +60 °C
    Humidity (Operating) 5% to 80% relative humidity (non-condensing) up to +31 °C. Upper limit derates to 50% relative humidity (non-condensing) at +40 °C.
    Humidity (Non-Operating) 5% to 95% relative humidity (non-condensing) as tested per MIL-PRF-28800F
    Altitude (Operating) Up to 10,000 ft. (3048 m) at or below +25 °C
    Altitude (Non-Operating) Up to 40,000 ft. (12,192 m)
    Random Vibration (Operating) 0.5 grms 5 Hz to 500 Hz, 15 minutes in each of three orthogonal axes
    Random Vibration (Non-Operating) 2.4 grms 5 Hz to 500 Hz, 15 minutes in each of three orthogonal axes
    Functional Shock 20 g peak, half sine, 11 ms pulse, 3 shocks (positive and negative) in each of three orthogonal axes, 18 shocks total

    Physical Dimensions

    Dimensions (HWD) 14"H x 18.4"W x 16"D (355 x 467 x 406 mm)
    Weight 51.5 lbs. (23.4 kg)
    Shipping Weight 70.0 lbs. (31.8 kg)

    FAQ:

    1.Can you ship order to Canada or Australia ?

    Yes,we can .We send orders worldwide .

    2. What delivery method do you use ? and delivery time ?

    We can ship by EMS,DHL,FedEx,UPS,TNT with tracking number. Usual delivery time is 4-7 workdays.

    3. What is your payment term?

    100% T/T payment before shipment.

    4. How can I ask any other question ?

    You can contact us online or leave us messages below .

    LeCroy 20GHz Digital Oscilloscope Practical WaveMaster SDA820Zi-ALeCroy 20GHz Digital Oscilloscope Practical WaveMaster SDA820Zi-ALeCroy 20GHz Digital Oscilloscope Practical WaveMaster SDA820Zi-ALeCroy 20GHz Digital Oscilloscope Practical WaveMaster SDA820Zi-ALeCroy 20GHz Digital Oscilloscope Practical WaveMaster SDA820Zi-A

    Quality LeCroy 20GHz Digital Oscilloscope Practical WaveMaster SDA820Zi-A for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Shenzhen Meigaolan Electronic Instrument Co. Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)